Setting the Dome Address (SW1 to SW4)
Document 800-05662V1 Rev A
04/11
ACUIX™ PTZ High Speed Analog Dome Installation and Configuration Guide
Each dome requires a unique address. The range of acceptable addresses is
determined by the type of controller you are using. Some controllers allow
addresses between 1 and 128, while others allow addresses between 1 and 256.
The address is set using the rotary DIP switches SW1, SW2, SW3, and SW4 on
the scan assembly circuit board (see
Figure 2-2
Switches SW1 to SW4
Each switch is assigned a place value (see
Table 2-2
Address Switch Assignments
Address
SW1
SW2
SW3
SW4
To set the dome address:
1. Remove the scan assembly from the pink antistatic bag it shipped in.
2. Using
Table 2-2
as a reference, turn the arrows on switches SW1, SW2,
SW3 and SW4 to select the address you want.
For example:
To set the dome address to 0001, set SW1=1, SW2=0, SW3=0, SW4=0.
To set the dome address to 0125, set SW1=5, SW2=2, SW3=1, SW4=0.
Note
If the address is set to 0000, the dome responds to control
commands for any address. For example, if an operator sends control
commands to address 0002, the dome that has the address 0000
performs the same commands.