There is a picture, but no control of the dome.
1. Ensure that DIP switches SW5 and SW6 on the scan assembly circuit board
are set for the correct protocol, baud rate, and parity. The dome must be set
the same as the control equipment.
2. Ensure that the controller is set to the correct dome address.
3. Power down all system components for 15 seconds and then re-apply
power to reset the dome. Manually control the dome and verify that the
dome finds home.
4. Ensure that:
the data wiring is connected at the terminal strip in the housing.
any bare wires are not touching each other.
the wire insulation is stripped back far enough for a good connection.
5. If none of the above works, try switching scan assemblies. If there are
multiple domes in the system, replace the scan assembly with a scan
assembly from another housing. Set the address of the replacement scan
assembly to the same address as the original scan assembly. Call up the
dome at the controller. If control returns, then the original scan assembly is
fault.
CAUTION
If a camera model is physically changed in a dome,
the configurations stored in the camera memory revert to the
default settings. In order to load the previous configurations to the
new dome requires two domes with the exact same camera model.