Table 2-4 Baud Rate And Parity Settings By Protocol; Table 2-5 Sw6 Baud Rate And Parity Settings - Honeywell ACUIX User Manual

Analog ptz high speed dome
Hide thumbs Also See for ACUIX:
Table of Contents

Advertisement

Setting the Baud Rate and Parity (SW6)
Document 800-05662V1 Rev A
04/11
ACUIX™ PTZ High Speed Analog Dome Installation and Configuration Guide
The baud rate and parity settings are determined by the protocol that you have
selected.
Table 2-4
lists the baud rate and parity settings that correspond to each
protocol.
Table 2-4
Baud Rate and Parity Settings by Protocol
Protocol
IntelliBus™
MAXPRO-mode (default)
VCL - RS485
VCL UTC
Diamond
Pelco P
Pelco D
Pelco P_AD
Pelco D_AD
The baud rate and parity are set using DIP switch SW6 (see
factory default is 9600 baud, even parity.
Table 2-5
SW6 Baud Rate and Parity Settings
Values
Baud Rate Switch Position
1
2
600
OFF
OFF
1200
ON
OFF
2400
OFF
ON
4800
ON
ON
9600
OFF
OFF
19200
ON
OFF
38400
OFF
ON
57600
ON
ON
115200
OFF
OFF
None
Even
Odd
* The default position for pins 7 and 8 is OFF (see
Baud Rate and Parity
38400 baud, no parity
9600 baud, even parity
9600 baud, no parity
9600 baud, no parity
9600 baud, even parity
4800 baud, no parity
2400 baud, no parity
4800 baud, no parity
2400 baud, no parity
Parity Switch
Position
3
4
5
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
ON
OFF
Table
2-1).
Table
2-5). The
Other*
6
7
8
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
7

Hide quick links:

Advertisement

Table of Contents
loading