Configuring Privacy Zones

Programming a Privacy Zone
Document 800-05662V1 Rev A
04/11
ACUIX™ PTZ High Speed Analog Dome Installation and Configuration Guide
Privacy zones allow you to prevent the viewing of sensitive areas (such as ATM
screens). A mask is superimposed over the area on the monitor screen where a
privacy zone is indicated, which moves with the dome's pan and tilt functions
and automatically resizes relative to the lens zoom setting.
Note
When a privacy zone is enabled, no video is displayed during the
finding home process. Privacy zones are not recognized until the
dome reaches home. After home is found, video is displayed on the
monitor unless a privacy zone overlaps with this home setting.
These instructions apply only to domes configured for MAXPRO-mode, VCL,
VCL UTC, Pelco P, or Pelco D protocol.
You can program up to 32 privacy zones.
To program a privacy zone:
1. Position the dome so that the area to be covered by the privacy zone is
displayed on the screen.
2. Select 6 Function Programming
3. Enter the 4-digit user login PIN or password (default = 1000).
4. Select a number between 1 and 32 to assign to the privacy zone. Privacy
zones are assigned priority in the order programmed. To change the
priority of a privacy zone, see
5. Press Focus Far to switch to PTZ control and adjust the coordinates of the
privacy zone as required using the joystick, moving it up or to the right to
create the mask.
The tilt cannot be greater than 70° and the zoom cannot be more than 1×.
Note:
6. Press Focus Near to switch to the OSD menu, and then press Iris Open to
save the coordinates.
7. Program another privacy zone or exit.
6 Program Privacy Zone.
Changing Privacy Zone Priority
below.