Configuring HDXG Camera Settings
42
To set the Manual AE mode:
1. Disable auto exposure (preset 92):
a. Exit the OSD menus until you have manual control of the dome.
b. Enter preset 92 on your controller to toggle auto exposure off.
2. Enter preset 90 on your controller to access the OSD main menu.
3. Select 5 Camera Options
4. Select one of the following options:
Iris (default): Provides manual iris control while the camera controls the
gain and shutter automatically.
Gain: Provides manual gain control while the camera controls the iris
and shutter automatically.
Full: Provides access to shutter speed, AGC level settings, and to
manual iris control.
Shutter: Provides manual shutter control while the camera controls the
iris and gain automatically.
5. If Full is selected, do the following:
a. Select 5 Camera Options
Settings.
Select the desired Shutter Speed:
NTSC = 1/60 (default), 1/120, 1/180, 1/250, 1/500, 1/1000, 1/2000, 1/4000,
1/10000, 1/30000
PAL = 1/50 (default), 1/100, 1/150, 1/250, 1/500, 1/1000, 1/2000, 1/4000,
1/10000, 1/30000
b. Select the desired AGC Level. Choose a value between 0 (default) and
30 dB.
c. Manually control the iris using Iris Open and Iris Close on your
controller.
To slow the AE response speed:
1. Select 5 Camera Options
Response.
2. Select a value between 1 (default) and 254 times.
2 Exposure Control
2 Exposure Control
2 Exposure Control
2 Manual AE Mode.
3 Full Manual
4 Slow AE