5.3
CONTROL OPTIONS, CONTINUED

5.3.5 Default Function

Select 5 to set the default function. The Default Function can be enabled or disabled.
To set the Default Function, enter values and select Enter (F5 on the HJZTP controller)
when done.
1 PASS ................................................ON
2 Auto-Pivot ........................................ON
3 Program Alarms
4 Set Pan and Tilt Options
5 Set Default Function
6 Auto Focus ......................................... Z
7 VectorScan Auto Focus ................ OFF
8 Pan Offset
ESC to Exit
If:
Default Function is disabled
Default Function is enabled,
and the scan is idle for the
programmed Delay setting
Alarms are present and the
scan reaches the delay
setting
Field
FUN (function)
NUM
(number)
DLY (delay
ENA (enable)
Rev. 1.02
CONTROL OPTIONS
Then:
Scan remains at its present position until the scan
receives a control command.
The scan performs the function (PreShot, VectorScan,
or Tour) programmed in the default function setup
menu after the programmed delay with no activity.
The scan automatically acknowledges the current
alarm, resets its delay timer, and then processes the
next alarm in numerical order. The scan processes all
alarms in this manner before performing the default
function.
Enter the function to perform after being idle for the specified delay
time. P = PreShot; V = VectorScan, T = Tour. See instructions
below for entering these functions in the FUN field.
Enter the PreShot number (0-99), VectorScan number (0-9), or
Tour number (1-3). Depending on the control system being used,
specific PreShots may be used for special setup and control
functions and are not available for the default function. Refer to
4
and
Table 5
for reserved PreShot numbers.
Enter the amount of time (minutes: seconds) the scan should be idle
before performing the default function. Maximum delay is 99 minutes
and 59 seconds.
Enter Y to enable or N to disable the default function.
DEFAULT FUNCTION SETUP
FUN
NUM
P
_1
PVT
Select 'Enter" when done.
Usage
35
DLY
ENA
_ _ : _ _
Y
MIN:SEC
Table
900.0679
22-June-2006

Hide quick links:

Advertisement

Table of Contents
loading