Honeywell HD6 Series User Manual page 47

Ptz camera in a dome
Hide thumbs Also See for HD6 Series:
Table of Contents

Advertisement

5.3
CONTROL OPTIONS, CONTINUED
3. Tilt Reverse – Select 3 to turn Tilt Reverse ON or OFF.
If:
Pan reverse is set to ON
Tilt reverse is set to ON
4. +2 Degree Tilt Limit –
Select 4 to turn +2 Degree Tilt Limit ON
or OFF. This allows the HD6 to tilt up 2
degrees above horizontal.
5. Find Home on Startup – Each unit has a
factory-set mechanical "HOME" position.
The receiver board uses the home
position as a reference point for the pan
and tilt positions.
Select 5 to turn Find Home on Startup
ON or OFF. If changing from OFF
(default) to ON, press Y when prompted.
To leave Find Home on Startup OFF,
press N when prompted.
If:
Find Home on Startup
is set to OFF (default)
Find Home on Startup is
set to ON
An operator can send a Scan to its home position at any time via the diagnostics
menu. Refer to paragraph 5.4.7.
Rev. 1.02
Then:
A left pan command causes the scan to pan right.
A right pan command causes the scan to pan left.
A tilt up command causes the scan to tilt down.
A tilt down command causes the scan to tilt up.
1 Manual Speed deg/s ...................... 400
2 Pan Reverse..................................... Off
3 Tilt Reverse ...................................... Off
4 +2 Deg Tilt Limit.............................. Off
5 Find Home on Startup..................... Off
6 Pan Offset ........................................ Off
ESC to Exit
ESC to Exit
Then:
When a Scan unit receives control data with its address the first
time after power-up, the scan finds home, and then performs the
control command.
The scan will find home after the initial startup delay has
counted down.