Scsi Off-Board Error; Scsi Lto Error - Motorola MVME162FX Programmer's Reference Manual

Embedded controller
Table of Contents

Advertisement

Description:
Parity error detected while the 53C710 was reading DRAM.
MPU Notification:
53C710 Interrupt.
Status:
53C710 DMA Status Register 53C710 DMA Interrupt Status
Register MC2 chip SCSI Error Status Register ($FFF4202C).
Comments:
53C710 interrupt enables are controlled in the 53C710 and in the
MC2 chip SCSI Interrupt Control Register ($FFF4202F).

SCSI Off-board Error

Description:
Error encountered while the 53C710 was attempting to go to the
VMEbus.
MPU Notification:
53C710 Interrupt.
Status:
53C710 DMA Status Register 53C710 DMA Interrupt Status
Register MC2 chip SCSI Error Status Register ($FFF4202C).
Comments:
53C710 interrupt enables are controlled in the 53C710 and in the
MC2 chip SCSI Interrupt Control Register ($FFF4202F).

SCSI LTO Error

Description:
Local Bus Time-out occurred while the 53C710 was local bus
master.
MPU Notification:
53C710 Interrupt.
Software Support Considerations