Toshiba Perfecptione Installation And Maintenance Manual page 87

Digital pbx
Table of Contents

Advertisement

9.63 Refer to the external device manufacturer' s
documentation for information on its SMDR con-
nector pin assignments.
9.64 The SMDR output speed can be set for either
300 bps or 1200 bps by the MDR switch on the front
panel of the LCCU PCB (Figure 4-72). SMDR pin
assignments are as follows:
FIGURE
4-72-LCCU
SWITCHES
9.70 The recording criteriaand account code length
are defined in DMDR Program (see Section 200-
255-300, Programming).
1 5 1 Clear to Send (to SMDR device)
I
6
Data Set Ready
7
Sianal Ground
1 8
I
Carrier Detect
I 20 I Data Terminal Readv (from SMDR device)
I
4-65
9.65 The code used by SMDR is standard 7-level
ASCII using one start bit, one stop bit and one parity
bit (even parity).
9.66 SMDR can be programmed to record data
under any one of the following conditions:
0 Incoming calls only.
l
Outgoing calls only.
l
Incoming and outgoing calls.
l
Outgoing toll calls only.
l
All incoming calls and outgoing toll calls.
9.71 Each time a trunk is seized, data is collected
for that call until the trunk is released. This data is
output at the SMDR port in thefollowingformat (see
Figure 4-73).
l
Time
l
Start of Call Hour - tens - units
Minute - tens - units
l
Call Duration Hour - units
Minute - tens- units
Seconds - tens - units
l
Condition Code (see table)
A =
Attendant handled
D =
Call > 10 hours
E =
Maintenance (SMDR port)
F =
Maintenance (trunk test)
I
=
Incoming call
K =
Outgoing call
L
=
Conference Attendant or 3-party
M =
Transfer or Call Forward
N =
SPCC #l
0
=
SPCC #2
P =
Date/Time change
Q =
System Initialize
R =
Incomplete call
S =
Date printed (every hour)
l
Access Code
3 digits maximum
INSTALLATION INSTRUCTIONS
SECTION 200-255-204
JANUARY 1993
9.67 When outgoing calls are chosen, all calls
seizing a trunk will be recorded regardless of dura-
tion. On incoming calls, all answered calls will be
recorded. Calls disconnected by Toll or Code Re-
striction features are not recorded.
9.68 Timing for recorded calls will start as follows
(Figure 4-73):
l
Outgoing-when trunk is seized.
l
Incoming to attendant only-when
attendant
answers.
l
Incoming and extended by the attendant-when
attendant answers.
l
Incoming to a station-when
answered.
9.69 A station user can enter a charge account
code of up to 12 digits for each call. This code is
included in the SMDR output.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Perfecptionex

Table of Contents