Toshiba Perfecptione Installation And Maintenance Manual page 213

Digital pbx
Table of Contents

Advertisement

PROGRAMMINGPROCEDURES
SECTION 200-255-311
FEBRUARY1992
TABLE114 (continued)
Error Codes
Proaram
Name:
DDIU Data Block (DDIU)
Error Code
I
Meaning
ERDIU 00
1 A PCB is not eauiooed
in that location.
ERDIU 01
The PCB is not an NDCU/NDKU
or NMDU type.
ERDIU 02
The oort is busv (REQ = CHG or OUT).
ERDIU 03
ERDIU 04
The port has already been assigned to a station, DSS console, DDIU, or PDIU (REQ = NEW).
#1 was entered, but tenant service was not enabled in the Svstem Data Block.
ERDIU 05
1 #l was entered, but Attendant #I was not programmed
(no Attendant
Data Block).
ERDIU 06
ERDIU 08
The button number is not allowed (exceeds maximum allowed for this DDIU/PDIU).
The maximum number of m
mbuttons
has already been assigned (maximum = 500).
ERDIU 10
ERDIU 11
The DN conflicts with the existing DN.
510 DNs have already been assigned in the system.
ERDIU 12
The DN has already been assigned to its maximum number of appearances
(maximum for a
Primary DN = 1; Secondary DN = 95).
ERDIU 14
ERDIU 16
ERDIU 17
The next hunt DN is not assigned.
The input DN has already been assigned to the port.
The input data was erased because the program was aborted during a NEW entry.
ERDIU 18
ERDIU 19
The port is not assigned.
Another type of data is assigned to the input port.
ERDIU 20
ERDIU 23
SDC has already been assigned to the input list.
The input DN is a trunk DN (VCP NNN HUNT DN).
ERDIU 24
ERDIU 33
The first digit of an input DN cannot be "0" or "9."
Only one DN can be assigned to a DIU.
ERDIU 34
I The port has already been assioned to a trunk.
11-5