PROGRAMMINGPROCEDURES
SECTION 200-255-310
FEBRUARY1992
TABLE10-4
Area/Office Code Exception Table
Load the
DTOL Utility Program.
When the TYPE prompt
is received,
proceed
as follows:
ITEM
PROMPT
USER ENTRY
NOTE
TYPE
AOC
Table Number
TN0
0 - 31
Area Code
ARC
NO/l X or NONE
1
Class Number
CNO
0 1 etc. or NONE
OFC
Off ice Codes
A
NXXX NXX etc., or
2&3
D
NXXX NXX etc.
NOTES:
1. ARC identifies
the area code to which this AOC is assigned.
Format is NO/lx
(N = 2 - 9, X = 0 -
9). A maximum
of eight AOC tables can be assigned
to any one area code, but the table numbers
(TNO) must be sequential.
2. Following
the OFC prompt,
the system will prompt
"A" and any office codes that are entered
will
be added.
To delete an office code, press them
key @.
The system will then prompt
"D"
and any entries that are made will be deleted.
Office codes entered
will be an exception
to the
listed area code and class. Ranges
are possible
(7309 = 730 - 739).
3. Codes
cannot
be added
and deleted
in the same pass through
the table. A separate
pass is
required
for each step.
4.
Ignore line entered.
Backspace.
= Stop printing
and return to REQ.
Exit program.
Error Codes
I
Program
Name:
Toll Restriction
Data Block (DTOLI
Error Code
ERTD 00
Meaning
Area code (NO/lx) is bevond ranae.
I
ERTD 01
1 Numeric error (0 - 9).
ERTD 02
ERTD 03
ERTD 05
Authorization
code is out of range (0 - 12).
Class number is out of range (0 - 7).
Number of entries exceeds the maximum (20).
I
ERTD 06
1 Table number is beyond range (0 - 31).
ERTD 07
ERTD 08
Class numbers exceed the maximum (8).
Office code does not exist.
10-7