Installing Ndtu - Toshiba Perfecptione Installation And Maintenance Manual

Digital pbx
Table of Contents

Advertisement

PERCEPTIONeb,,
Tl/OS-1
SEPTEMBER 1991
3.20 Installing
NDTU
3.21 The installation
of NDTU MUST be done in
conjunction
with
NTWU-3
and the D.O1, or higher-
level software.
WARNING!
Hazardous
voltage
that may cause
death
or injury
is exposed
at the power
supply
AC terminal.
1) Install NDTU in position TOO in the main cabi-
net, and/or TO8 in the expansion
cabinet.
2) The NDTU
PCB can support
24 trunks
of
different
types (CO, DID, TIE).
3) If all 24 trunks are used, DO NOT insert any
PCBs in the next five trunk slots after TOO or
T08.
NOTES:
When programming
the trunks assigned
to
the NDTU PCB, please keep the following
in
mind:
1. If the PERCEPT/ON
system is NOT con-
nected
to a live Tl span, there are two
options to consider:
l
Set the NDTU
for Loop
Back testing
(see Paragraph
3.70)
and program
the
trunks, or
l
Place an analog
trunk PCB in slot TOO
or TO8, and program
the four circuits on
the PCB. Then remove the analog trunk
PCB, insert the NDTU
PCB, and pro-
gram the rest of the trunks.
2. If the PERCEPTION
system is connected
to a live Tl span, the NDTU can be in-
stalled
and programmed
in the normal
manner,
4) If less than 24 trunks (in multiples
of four) are
used, utilize the remaining
slots for the desig-
nated application
as defined in the Installation
section (Chapter4)
of the PERCEPTIONe&ex
installation
and Maintenance
manual.
5) Connect
the provided
coax clock cable be-
tween the NDTU (J3) and NTWU-3 (J2) PCBs
for the first span.
6) If two Tl spans
are used, the NDTU con-
nected
to the best clock source
should
be
cabled to the NTWU-3
(primary span).
3.30 Connecting
to Channel
Service
Unit
3.31 The CSU/DSU
(Channel
Service
Unit/Data
Service
Unit) provides
an electrical
protection,
a
keep-alive
signal,
and a repeater
function.
The
CSU can still be network powered
per FCC require-
ments. The DSU provides
the physical conversion
(V.35 or RS449/422
to DSI),
"ONE" density,
and
D4 or ESF (Extended
Super-frame)
framing
(see
Figure 5 and Attachment
A).
PERCEPTIONeaex
FIGURE 5-DS-1 CONNECTION TO DIGITAL
NETWORK
WARNING!
Hazardous
voltage
that may cause
death
or injury
is exposed
at the power
supply
AC terminal.
1) Use the
cable
provided
with
the NDTU
PCB to connect
the
PERCEPTIONekex
cabinet
to the CSU.
2) Connect
the 50-pin amphenol
to the PBX (see
Table 4).
-6-

Advertisement

Table of Contents
loading

This manual is also suitable for:

Perfecptionex

Table of Contents