Cisco 3200 Use And Care Manual page 201

Cisco systems telepresence system installation guide
Hide thumbs Also See for 3200:
Table of Contents

Advertisement

Chapter 10
First-Time Setup
Step 3
Lightly tap each microphone and watch the audio meter on the corresponding display screen to see that
sound registers.
This step verifies that the microphones are connected and operating properly.
Calibrate the microphones by clicking the Microphone Calibration button.
Step 4
The room must be completely quiet to properly calibrate microphones and ensure that camera switching
Note
is properly enabled.
Tip
Before clicking the Microphone Calibration button, you can leave the room and close the door to insure
complete silence in the room.
Click Refresh Microphones Status to update the on/off status of all microphones.
Step 5
Click Stop when setup is complete.
Step 6
Troubleshooting Microphones
Use
Table 10-4
Table 10-4
Problem
Sound is muffled.
Sound registers at the wrong
microphone.
OL-14521-01
to troubleshoot problems with microphones.
Troubleshooting Chart for Microphone Problems
Possible Cause
Something near or on the
microphone is distorting the
sound.
Microphone cable is not
connected to its corresponding
codec.
Setting Up CTS Components
Possible Solution
Move objects away from the
microphone.
Check that the cable from the
microphone is plugged into the
correct receptor on the codec.
Plug all microphones into the
primary codec.
Cisco TelePresence System 3200
10-19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Telepresence 3200

Table of Contents