DCP551 Parameter Work Sheet
No.
Item code
C 29
29
Selections available when power
is on during PV channel switching
C 30
30
PV equalizer
C 31
31
End of operation
C 32
32
Manipulated variable in READY mode 0.0
C 33
33
Manipulated variable setting
in PV overrange
C 34
34
Manipulated variable in PV
overrange
C 35
35
MANUAL change mode
C 36
36
Preset MANUAL value
C 43
43
Service interruption time when running can be continued
C 45
45
Auxiliary output 1 type
C 46
46
Auxiliary output 1 lower limit (4mA) 0 SPU
C 47
47
Auxiliary output 1 upper limit (20mA) 10000 SPU
C 48
48
Auxiliary output 2 type
C 49
49
Auxiliary output 2 lower limit (4mA) 0 SPU
C 50
50
Auxiliary output 2 upper limit (20mA) 10000 SPU
C 52
52
SP output lower limit (4mA)
C 53
53
SP output upper limit (20mA)
C 57
57
Programming item
Event
C 58
58
Programming item
PID group, output limiter group
C 59
59
Programming item
G.SOAK, PV shift, repeat
C 60
60
Programming item
PV start, cycle, pattern link
C 61
61
Programming system
C 62
62
Program time unit
C 63
63
Time display (display panel 2)
C 65
65
SP decimal point position
denotes items settable only on models with two PV input channels.
12
Item
Factory default
settings
0
0
0
0
0.0
0
0.0
0
0
0
0 SPU
10000 SPU
0
0
0
0
0
0
0
1
User
Settings and descriptions
-
settings
0 : Continues until power is turned off.
1 : PV1
2 : PV2
3 : High-temperature PV
4 : Low-temperature PV
0 : Not provided
1 : PV1 only
2 : PV2 only
3 : Both PV1 and PV2
0 : READY mode
1 : END mode
–5.0 to +105.0%
0 : Not provided
1 : Provided
–5.0 to +105.0%
0 : Smooth
1 : Preset
–5.0 to +105.0%
0 to 3600sec
0 : SP
1 : PV
2 : Deviation (DEV)
3 : Manipulated variable (MV)
4 : PV1
5 : PV2
–19999 to +20000 SPU (
–1999.9 to +2000.0% (
–19999 to +20000 SPU (
–1999.9 to +2000.0% (
0 : SP
1 : PV
2 : Deviation (DEV)
3 : Manipulated variable (MV)
4 : PV1
5 : PV2
–19999 to +20000 SPU (
–1999.9 to +2000.0% (
–19999 to +20000 SPU (
–1999.9 to +2000.0% (
–19999 to +20000 SPU
–19999 to +20000 SPU
0 : Displayed
1 : Not displayed
0 : Displayed
1 : Not displayed
0 : Displayed
1 : Not displayed
0 : Displayed
1 : Not displayed
0 : RAMP-X and RAMP-T (θ) combined
1 : RAMP-X and RAMP-E (∆SP) combined
0 : Hours, min (SPU/hour for RAMP-T)
1 : Min, sec (SPU/min for RAMP-T)
2 : 0.1 sec (SPU/sec for RAMP-T)
0 : Remaining segment time
1 : total operation time (after READY → RUN start)
0 to 4
C45
not equal to 3)
C45
set to 3)
C45
not equal to 3)
C45
set to 3)
C48
not equal to 3)
C48
set to 3)
C48
not equal to 3)
C48
set to 3)