Chapter 7. PARAMETER SETUP
No.
Item code
24
Unused
PA 24
25
Unused
PA 25
26
Unused
PA 26
27
Unused
PA 27
28
Unused
PA 28
29
Unused
PA 29
30
Unused
PA 30
31
Event on delay
PA 31
Group 1 event number
32
Event on delay
PA 32
Group 1 delay time
33
Event on delay
PA 33
Group 2 event number
34
Event on delay
PA 34
Group 2 delay time
35
Event on delay
PA 35
Group 3 event number
36
Event on delay
PA 36
Group 3 delay time
37
Event on delay
PA 37
Group 4 event number
38
Event on delay
PA 38
Group 4 delay time
39
FAST X
PA 39
40
Unused
PA 40
41
EG1 LED display event
PA 41
number
42
EG2 LED display event
PA 42
number
43
PID computation initialize
PA 43
44
Unused
PA 44
45
Unused
PA 45
46
G.SOAK time
PA 46
47
Unused
PA 47
48
Unused
PA 48
49
Unused
PA 49
7-6
Factory default
Item
settings
-----
-----
-----
-----
-----
-----
-----
0
0.0
0
0.0
0
0.0
0
0.0
0
-----
0
0
0
----
----
2.0
----
----
----
User
Settings and descriptions
settings
[Description:]
Ò-----Óis displayed and setting cannot be performed.
0 to 16
[Description:]
A setting of 0 generates no delay.
0.0 to 3000.0sec
[Description:]
When
is set to 0, Ò-----Ó is displayed and setting cannot be performed.
PA31
0 to 16
[Description:]
A setting of 0 generates no delay.
0.0 to 3000.0sec
[Description:]
When
is set to 0, Ò-----Ó is displayed and setting cannot be performed.
PA33
0 to 16
[Description:]
A setting of 0 generates no delay.
0.0 to 3000.0sec
[Description:]
When
is set to 0, Ò------Ó is displayed and setting cannot be performed.
PA35
0 to 16
[Description:]
A setting of 0 generates no delay.
0.0 to 3000.0sec
[Description:]
When
is set to 0, Ò-----Ó is displayed and setting cannot be performed.
PA37
0 : 2X
1 : 10X
2 : 60X
3 : 120X
[Description:]
When setup data
is set to 1 (program time unit: minutes,
C62
seconds), settings 3 and 4 produce a speed of 10 X.
When
is set to 2 (program time unit: 0.1sec), the FAST
C62
mode is not available.
[Description:]
Ò-----Óis displayed and setting cannot be performed.
0 to 16
[Description:]
A setting of 0 turns off the EG1 LED.
0 to 16
[Description:]
A setting of 0 turns off the EG2 LED.
0: No initialization during advance processing and PID group
change.
1: Initializes during advance processing but not during PID
group change.
2: No initialization during advance processing but initializes
[Description:]
Ò-----Óis displayed and setting cannot be performed.
0.1 to 60.0sec