No.
Item code
E12-t
34
Event 12 event type
E12-1
35
Event 12 auxiliary setting 1
E12-2
36
Event 12 auxiliary setting 2
E13-t
37
Event 13 event type
E13-1
38
Event 13 auxiliary setting 1
E13-2
39
Event 13 auxiliary setting 2
E14-t
40
Event 14 event type
E14-1
41
Event 14 auxiliary setting 1
E14-2
42
Event 14 auxiliary setting 2
E15-t
43
Event 15 event type
E15-1
44
Event 15 auxiliary setting 1
E15-2
45
Event 15 auxiliary setting 2
E16-t
46
Event 16 event type
E16-1
47
Event 16 auxiliary setting 1
E16-2
48
Event 16 auxiliary setting 2
Event type
Event
Meaning
type
0
Event off
1
Time event
2
PV upper limit
3
PV lower limit
4
Deviation upper limit
5
Deviation lower limit
6
Deviation upper limit with standby
7
Deviation lower limit with standby
8
Absolute value deviation upper limit
9
Absolute value deviation lower limit
10
Absolute value deviation upper limit with standby
11
Absolute value deviation lower limit with standby
12
PV deviation rate upper limit
13
PV deviation rate lower limit
14
SP upper limit
15
SP lower limit
16
MV upper limit
17
MV lower limit
18
Code event
19
SOAK absolute value deviation upper limit
20
SOAK absolute value deviation lower limit
21
SOAK absolute value deviation upper limit with standby
22
SOAK absolute value deviation lower limit with standby
23
Code event with timer
Item
Factory default
settings
0
-----
-----
0
-----
-----
0
-----
-----
0
-----
-----
0
-----
-----
Setting
Operation
category
category
-----
-----
Segment
Time
Segment
PV
Segment
PV
Segment
PV
Segment
Code
Segment
PV
Segment
Code time
DCP551 Parameter Work Sheet
User
Settings and descriptions
-
settings
0 to 253
–19999 to +20000
(Setting range is variable according to the event types.)
–19999 to +20000
(Setting range is variable according to the event types.)
0 to 253
–19999 to +20000
(Setting range is variable according to the event types.)
–19999 to +20000
(Setting range is variable according to the event types.)
0 to 253
–19999 to +20000
(Setting range is variable according to the event types.)
–19999 to +20000
(Setting range is variable according to the event types.)
0 to 253
–19999 to +20000
(Setting range is variable according to the event types.)
–19999 to +20000
(Setting range is variable according to the event types.)
0 to 253
–19999 to +20000
(Setting range is variable according to the event types.)
–19999 to +20000
(Setting range is variable according to the event types.)
Auxiliary settings
: None
Auxiliary 1
: None
Auxiliary 1
: Hysteresis
Auxiliary 1
: Sampling cycle
Auxiliary 1
: Hysteresis
Auxiliary 1
: No. of output
Auxiliary 1
: Hysteresis
Auxiliary 1
: No. of output
Auxiliary 1
: None
Auxiliary 2
: None
Auxiliary 2
: None
Auxiliary 2
: None
Auxiliary 2
: None
Auxiliary 2
: None
Auxiliary 2
: None
Auxiliary 2
: None
Auxiliary 2
5