Distance-amplitude curve according to JIS Z3060-2002 (JISDAC)
– Finally, select the function FINISH and press one of
the selector keys to finish the recording of the DAC
echoes. The finishing is confirmed by the indication
(STORED).
USM 36

Setting up JISDAC

– Select the function group SETUP. The function JIS-
DAC is automatically set to ON.
– Select the function BOLD LINE and
press one of the selector keys to choose the required
evaluation line.
– Select the function group GATE A and position the
gate in the expectancy range of the echoes.
– Adjust the gain.
Issue 2 (12/2013)