Mounting; Technical Data - Bosch DCN Next Generation Installation And User Instructions Manual

Digital congress network
Hide thumbs Also See for DCN Next Generation:
Table of Contents

Advertisement

DCN NG | Installation and User Instructions | Section 3 | Central Control Equipment
9.4

Mounting

The extension power supply is suitable for either
table-top or 19 inch rack mounted use. The unit can
only be rack-mounted when two extension power
supplies are used. The units are attached to each other
using a supplied metal plate that joins the units together
at the front and rear. Once joined, the unit can be
mounted using the mounting brackets supplied with
each unit.
P ow
er
figure 9.7: Mounting
Bosch Security Systems | 2004-03 | 9922 141 70521en
P ow
er
9.5

Technical data

9.5.1
Physical characteristics
Dimensions (H x W x D):
100 x 220 x 308 mm (excl. brackets)
Depth including brackets:
348 mm
Weight:
8.3 kg
9.5.2
Power consumption
Power consumption:
0.7 W
9.5.3
Climate conditions
Temperature:
5 to 45 °C (operating)
-20 to 70 °C (storage)
Relative humidity:
max. 95%
Air pressure:
600 to 1100 hPa
9.5.4
Mains inlet
Number of connections:
1x IEC male mains inlet with fuse holder
Position:
Rear side
Fuse:
T5A 125 V (100 - 120 V (AC))
T4A H 230 V (220 - 240 V(AC))
Input voltage (selectable):
105, 115, 125, 220, 230 and 240 V(AC)
9.5.5
DCN connections
Number of connections:
3x DIN-6 female DCN socket
1x DCN cable (2 m) with male connector
Power supply:
3 x 85 W (on DCN sockets)
Position:
Rear side
en | 80