DCN NG | Installation and User Instructions | Section 5 | System Installation
2150
2050
1950
1850
1750
1650
1550
1450
1350
1250
1150
1050
950
0
5
figure 27.3: Maximum optical fiber length vs. number of nodes
27.5.4 Bending
The bend radius of a 90 degree bend is 25 mm (see
figure 27.4). A 180 degree bend equals two bends.
R=25 mm
figure 27.4: Bend radius
Bosch Security Systems | 2004-03 | 9922 141 70521en
10
15
20
25
Number of nodes
30
35
40
45
27.5.5 Coiling
The minimum coiling radius is 100 mm (see
figure 27.5).
figure 27.5: Coiling radius
en | 142
50
55
60
R=100 mm