DCN NG | Installation and User Instructions | Section 3 | Central Control Equipment
8.6.7
Set nominal level
The Nominal Level menu item is used to change the
nominal levels for the audio inputs and outputs. The
nominal level shown applies to the XLR sockets.
(Nominal level cinch = nominal level XLR - 12 dB.)
Furthermore, the submenu provides level meters for a
visual identification of the signal strength.
table 8. 1 0: Nominal Level submenu (* = default)
Menu item
3A Nom. Level ...
3A Nom. Level
8.6.8
Initialize the system
The Initialize menu item is used to initialize all units
connected to the DCN sockets. All system units will
need a new address after this action. The initialisation
process is started by entering the submenu and
confirming your choice.
Note
All system units that must be initialized must be
connected before executing this function.
table 8. 1 1: Initialize submenu (* = default)
Menu item
3B Initialize ...
3B Initialize
Bosch Security Systems | 2004-03 | 9922 141 70521en
Option
Value 1
Source:
- Input nn
Input nr:
1, 2
- Output nn
Output nr:
1, 2
Options
Description
Push the button to go the submenu.
Are you sure:
- No*
Cancel initialisation.
- Yes
Start initialisation of the system.
Value 2
Description
Push the button to
go to the submenu.
Level:
The nominal level for
-24 to -12 dBV
audio input nn.
(-18 dBV*)
Level:
The nominal level for
-42 to -12 dBV
audio output nn.
(-18 dBV*)