Mounting; Operation; Technical Data - Bosch DCN Next Generation Installation And User Instructions Manual

Digital congress network
Hide thumbs Also See for DCN Next Generation:
Table of Contents

Advertisement

DCN NG | Installation and User Instructions | Section 4 | Installation Accessories
18.4

Mounting

The network splitter can be mounted to a wall or any
other flat surface using a bracket (see figure 18.6). The
distance (d) between the holes in the bracket is 40 mm.
figure 18.6: Mounting
Press the sides of the unit to snap it in and out of the
bracket.
18.5

Operation

The two LEDs on the network splitter provide
information about the status of the network splitter.
table 18.2: Status LED indicators
Green
Yellow
(Power)
(Fault)
Off
Off
Off
On
On
Off
Bosch Security Systems | 2004-03 | 9922 141 70521en
Status
No power
No optical network or
optical network fault
Functioning correctly
18.6

Technical data

18.6.1 Physical characteristics
Dimensions (H x W x D):
200 x 82.5 x 28.9 mm
Weight:
approx. 300 g
18.6.2 Climate conditions
Temperature:
-5 to 45 °C (operating)
-20 to 70 °C (transport, handling and storage)
Relative humidity:
15 to 90% (operating)
5 to 95% (transport, handling and storage)
Air pressure:
600 to 1100 hPa
18.6.3 Power consumption
Power consumption:
3.9 W
18.6.4 Optical network connections
Number of connections:
4x proprietary female sockets
Position:
Front and rear sides
18.6.5 External power supply
Number of connections:
1x 4 pin female socket
Position:
Rear side
Input voltage:
48 V(DC)
Input voltage range:
28 to 48 V(DC)
Current:
max. 5 A
en | 112