DCN NG | Installation and User Instructions | Section 4 | Installation Accessories

20.4 Wiring

See figure 20.5 for details about the wires inside the
extension cables.
3
2
1
figure 20.5 Cable details
table 20.3: Cable details
Number
Signal
1
Protective cloth
2
Insulation
3
Outer sheet
4
Stranded wire
5
Insulation
6
Optical fiber

20.5 Custom-made cables

Use LBB4418/00 Cable-connector Tool Kit to create
custom-made cables out of LBB4416/00 Network
Cables and LBB4417/00 Network Connectors.
Bosch Security Systems | 2004-03 | 9922 141 70521en
4
5
6
7±0. 1
Color
----
Brown
Black
-----
Red
-----

20.6 Technical data

Insulation:
LSZH (low smoke/zero halogen), black
Outer diameter:
7 mm
Power supply wires (2):
2
Copper, stranded 1 mm
resistance < 0.018 Ω/m
Optical fibers (2):
• PMMA, 1 mm diameter including cladding, 2 mm
diameter including insulation
• black numeric aperture = 0.5
• optical attenuation < 0. 1 7 dB/m @ 650 nm
• bending loss < 0.5 dB (r = 20 mm, 90°), according
to JIS C6861
Temperature range:
-40 to +65 °C
Pull force:
max. 150 N
UL-compliancy:
UL444 (60 °C/60 V), UL1666
Flame retardant:
according to IEC 60332-1 / 60 s
Halogen level:
according to IEC 60754-2, pH > 4.3 and
conductivity < 10 uS/mm
Smoke level:
according to IEC 61034-2, light transmittance > 60%