r1149

CO: Ramp-function generator acceleration / RFG acceleration

VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Setpoints
Not for motor type: -
Min
- [rev/s²]
Description:
Displays the acceleration of the ramp-function generator.
Dependency:
Refer to: p1145
r1150
CO: Ramp-function generator speed setpoint at the output / RFG n_set at outp
VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Setpoints
Not for motor type: -
Min
- [rpm]
Description:
Displays the setpoint at the output of the ramp-function generator.
p1151[0...n]

Ramp-function generator configuration / RFG config

VECTOR_G
Can be changed: U, T
Data type: Unsigned16
P-Group: Setpoints
Not for motor type: -
Min
-
Description:
Sets the configuration for the extended ramp-function generator.
Bit field:
Bit
00
01
02
Dependency:
Re bit 01, 02 = 1:
These bits are only effective when ramp-function generator tracking is activated (p1145 > 0).
When both bits are activated, RFG tracking with polarity change is active.
Re bit 01 = 0, bit 02 = 0:
When ramp-function generator tracking is active, the setpoint can only change in the direction of the target setpoint –
or be frozen.
Notice:
Re bit 00 = 1:
If the ramp-up time is longer than the ramp-down time (p1120 > p1121), then there is an acceleration step at the zero
crossover. This can have a negative impact on the mechanical system.
Note:
Re bit 00 = 1:
When the direction change is changed there is no rounding-off before and after the zero crossover.
Re bit 01 = 1:
For load surges, the ramp-function generator output tracks the actual value. The tracking (correction) ends at a
setpoint of zero.
Re bit 02 = 1:
For load surges, the ramp-function generator output tracks the actual value. For a polarity change, the tracking
(correction) is continued.
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Signal name
Disable rounding-off at the zero cross-over
RFG tracking without polarity change
RFG tracking with polarity change
Calculated: -
Dyn. index: -
Units group: 39_1
Scaling: p2007
Max
- [rev/s²]
Calculated: -
Dyn. index: -
Units group: 3_1
Scaling: p2000
Max
- [rpm]
Calculated: -
Dyn. index: DDS, p0180
Units group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: 3060, 3070
Unit selection: p0505
Expert list: 1
Factory setting
- [rev/s²]
Access level: 3
Func. diagram: 3001, 3080
Unit selection: p0505
Expert list: 1
Factory setting
- [rpm]
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0000 bin
0 signal
No
No
No
FP
3070
-
-
309