r4979[0...n]

OA invalid error code / OA inv error code

CU_G130_DP,
Can be changed: -
CU_G130_PN,
Data type: Unsigned32
CU_G150_DP,
P-Group: OEM range
CU_G150_PN
Not for motor type: -
Min
-
Description:
Displays the error code of the invalid OA applications installed on the memory card/device memory.
r4979[0]: Fault value of OA application 1
r4979[1]: Fault value of OA application 2, ...
Dependency:
Refer to: r4975, r4976, r4978
Notice:
If there is no invalid OA application, then it is not possible to access an index.
Note:
The value in the error code must be interpreted in binary form. The bits have the following meaning:
Bit 0: Incompatible OA interface version.
Bit 1: OA application could not be loaded.
Bit 2: Incorrect description files.
Bit 3: OA application does not define a CPU type.
Bit 4: OA application for this device not supported (incorrect CPU type).
Bit 5: OA application for this device not supported (incorrect type ID).
Bit 6: Incorrect description files (Const/Startup incompatible).
r4985

OA number / OA no

CU_G130_DP,
Can be changed: -
CU_G130_PN,
Data type: Unsigned16
CU_G150_DP,
P-Group: OEM range
CU_G150_PN
Not for motor type: -
Min
0
Description:
Displays the number of OA applications installed on the memory card/device memory.
Dependency:
Refer to: r4986, r4987, r4988, r4989, r4990, r4991, r4992, r4993, r4994
Note:
OA: Open Architecture (OA application)
r4986

OA identifier total length / OA id tot_length

CU_G130_DP,
Can be changed: -
CU_G130_PN,
Data type: Unsigned16
CU_G150_DP,
P-Group: OEM range
CU_G150_PN
Not for motor type: -
Min
0
Description:
Displays the total length of the IDs of all the OA applications installed on the memory card/device memory.
Dependency:
Refer to: r4985, r4987, r4988, r4989, r4990, r4991, r4992, r4993, r4994
Note:
The identifier of an OA application comprises a maximum of 8 characters plus separator.
r4987

OA GUID total length / OA GUID tot_length

CU_G130_DP,
Can be changed: -
CU_G130_PN,
Data type: Unsigned16
CU_G150_DP,
P-Group: OEM range
CU_G150_PN
Not for motor type: -
Min
0
Description:
Displays the total length of the GUIDs of all the OA applications installed on the memory card/device memory.
Dependency:
Refer to: r4985, r4986, r4988, r4989, r4990, r4991, r4992, r4993, r4994
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Calculated: -
Dyn. index: r4975
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
16
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
144
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
288
2 Parameters
2.2 List of parameters
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-