2 Parameters
2.2 List of parameters
p7763
KHP OEM exception list number of indices for p7764 / KHP OEM qty p7764
All objects
Can be changed: U, T
Data type: Unsigned16
P-Group: -
Not for motor type: -
Min
1
Description:
Sets the number of parameters for the OEM exception list (p7764[0...n]).
p7764[0...n], with n = p7763 - 1
Dependency:
Refer to: p7764
Note:
KHP: Know-How Protection
Even if know-how protection is set, parameters in this list can be read and written to.
p7764[0...n]
KHP OEM exception list / KHP OEM excep list
B_INF, ENC, HUB,
Can be changed: U, T
TB30, TM150, TM31,
Data type: Unsigned16
TM54F_MA,
P-Group: -
TM54F_SL,
Not for motor type: -
VECTOR_G
Min
0
Description:
OEM exception list (p7764[0...n] for setting parameters that should be excluded from know-how protection.
p7764[0...n], with n = p7763 - 1
Dependency:
The number of indices depends on p7763.
Refer to: p7763
Note:
KHP: Know-How Protection
Even if know-how protection is set, parameters in this list can be read and written to.
p7764[0...n]
KHP OEM exception list / KHP OEM excep list
CU_G130_DP,
Can be changed: U, T
CU_G130_PN,
Data type: Unsigned16
CU_G150_DP,
P-Group: -
CU_G150_PN
Not for motor type: -
Min
0
Description:
OEM exception list (p7764[0...n] for setting parameters that should be excluded from know-how protection.
p7764[0...n], with n = p7763 - 1
Dependency:
The number of indices depends on p7763.
Refer to: p7763
Note:
KHP: Know-How Protection
Even if know-how protection is set, parameters in this list can be read and written to.
p7765
KHP configuration / KHP config
CU_G130_DP,
Can be changed: U, T
CU_G130_PN,
Data type: Unsigned16
CU_G150_DP,
P-Group: -
CU_G150_PN
Not for motor type: -
Min
-
Description:
Configuration settings for know-how protection.
720
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
500
Calculated: -
Dyn. index: p7763
Units group: -
Scaling: -
Max
65535
Calculated: -
Dyn. index: p7763
Units group: -
Scaling: -
Max
65535
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
List Manual (LH2), 04/2014, A5E03263479A
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
1
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
[0] 7766
[1...499] 0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0000 bin
SINAMICS G130/G150