Trace Number Of Recorded Values / Trace Rec Values; Trace Record Signal 0 / Trace Record Sig 0; Trace Record Signal 1 / Trace Record Sig 1; Trace Record Signal 2 / Trace Record Sig 2 - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
Index:
[0] = Trace 0
[1] = Trace 1
r4729[0...1]

Trace number of recorded values / Trace rec values

CU_G130_DP,
Can be changed: -
CU_G130_PN,
Data type: Unsigned32
CU_G150_DP,
P-Group: Trace and function generator
CU_G150_PN
Not for motor type: -
Min
-
Description:
Displays the number of traced values for each signal.
Index:
[0] = Trace 0
[1] = Trace 1
Dependency:
Only valid when p4705 = 4.
p4730[0...5]

Trace record signal 0 / Trace record sig 0

CU_G130_DP,
Can be changed: U, T
CU_G130_PN,
Data type: Unsigned32
CU_G150_DP,
P-Group: Trace and function generator
CU_G150_PN
Not for motor type: -
Min
-
Description:
Selects the first signal to be traced.
Index:
[0] = Trace 0 parameter in BICO format
[1] = Trace 1 parameter in BICO format
[2] = Trace 0 PINx with DO Id and chart Id
[3] = Trace 0 PINx with block Id and PIN Id
[4] = Trace 1 PINy with DO Id and chart Id
[5] = Trace 1 PINy with block Id and PIN Id
p4731[0...5]

Trace record signal 1 / Trace record sig 1

CU_G130_DP,
Can be changed: U, T
CU_G130_PN,
Data type: Unsigned32
CU_G150_DP,
P-Group: Trace and function generator
CU_G150_PN
Not for motor type: -
Min
-
Description:
Selects the second signal to be traced.
Index:
[0] = Trace 0 parameter in BICO format
[1] = Trace 1 parameter in BICO format
[2] = Trace 0 PINx with DO Id and chart Id
[3] = Trace 0 PINx with block Id and PIN Id
[4] = Trace 1 PINy with DO Id and chart Id
[5] = Trace 1 PINy with block Id and PIN Id
p4732[0...5]

Trace record signal 2 / Trace record sig 2

CU_G130_DP,
Can be changed: U, T
CU_G130_PN,
Data type: Unsigned32
CU_G150_DP,
P-Group: Trace and function generator
CU_G150_PN
Not for motor type: -
Min
-
Description:
Selects the third signal to be traced.
Index:
[0] = Trace 0 parameter in BICO format
[1] = Trace 1 parameter in BICO format
[2] = Trace 0 PINx with DO Id and chart Id
662
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
List Manual (LH2), 04/2014, A5E03263479A
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0
SINAMICS G130/G150

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130

Table of Contents