p0492

Square-wave encoder maximum speed difference per sampling cycle /

n_dif max/samp_cyc
ENC
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Encoder
Not for motor type: -
Min
0.00 [rpm]
Description:
Sets the maximum permissible speed difference within the current controller sampling time for squarewave
encoders.
Note:
For a value of 0.0, the speed change monitoring is disabled.
if the set maximum speed difference is only exceeded for one sampling time of the current controller, then an
appropriate alarm is output. However, if the maximum speed difference is exceeded over several sampling times,
then a corresponding fault is output.
p0492

Square-wave encoder max. velocity difference per sampling cycle /

v_dif max/samp_cyc
ENC (Lin_enc)
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Encoder
Not for motor type: -
Min
0.00 [m/min]
Description:
Sets the maximum permissible velocity difference within the current controller sampling time for square-wave
encoders.
Note:
For a value of 0.0, velocity change monitoring is disabled.
if the set maximum velocity difference is only exceeded for one sampling time of the current controller, then an
appropriate alarm is output. However, if the maximum speed difference is exceeded over several sampling times,
then a corresponding fault is output.
p0492

Maximum speed difference per sampling cycle / n_dif max/samp_cyc

VECTOR_G
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Encoder
Not for motor type: -
Min
0.00 [rpm]
Description:
Sets the maximum permissible speed difference within the current controller sampling time.
Dependency:
Refer to: r1408
Note:
For a value of 0.0, the speed change monitoring is disabled.
The following applies for square-wave encoders:
If the speed difference exceeds the threshold value p0492, depending on p0491, either encoderless closed-loop
speed/torque control is selected or the drive is powered down with fault F3x118.
The following applies for other speed encoders:
If the speed difference exceeds threshold value p0492, in order to avoid subsequent faults, the old speed actual
value is kept and after time p2178 shut down with fault F07902 (motor stalled).
198
Calculated: CALC_MOD_REG
Dyn. index: -
Units group: -
Scaling: -
Max
210000.00 [rpm]
Calculated: CALC_MOD_REG
Dyn. index: -
Units group: -
Scaling: -
Max
1000.00 [m/min]
Calculated: CALC_MOD_REG
Dyn. index: -
Units group: -
Scaling: -
Max
210000.00 [rpm]
List Manual (LH2), 04/2014, A5E03263479A
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0.00 [rpm]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0.00 [m/min]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0.00 [rpm]
SINAMICS G130/G150

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130

Table of Contents