p0212
Power unit configuration / PU config
VECTOR_G
Can be changed: C2(2)
Data type: Unsigned16
P-Group: Converter
Not for motor type: -
Min
-
Description:
Sets the power unit configuration.
Bit field:
Bit
00
01
03
05
Dependency:
Re bit 00:
Reduced supply voltages are only possible for booksize and chassis power units (DC/AC).
Bit 0 = 1 can only be set if r0192.22 = 1.
Re bit 01 = 1:
The external pre-charging setting only affects the DC/AC power units.
Re bit 03 = 1:
The automatic adaptation (reduction) of the Vdc max limit is deactivated (only for chassis power units). Bit 3 only has
an effect, if bit 0 is simultaneously set.
Refer to: r0192, p0210
Caution:
Re bit 00:
Working with reduced input voltages de-activates undervoltage detection.
Re bit 03:
If the automatic setting of the Vdc max limit is deactivated, then all of the components connected to the DC link must
be suitable for the maximum DC link voltage of the power unit (e.g. 820 V for 400 V units).
Note:
Re bit 00 = 0:
It is not possible to reduce the supply voltage in p0210.
Re bit 00 = 1:
With this setting the supply voltage in p0210 can be reduced to 100 V.
Booksize PU: only for operating mode p1300 = 19
Chassis PU: only for operating mode p1300 > 19 and closed-loop DC voltage control
Re bit 01 = 0:
There is no external pre-charging of the DC/AC Motor Modules. The pre-charging monitoring is bypassed.
Re bit 01 = 1:
There is external pre-charging of the DC/AC Motor Modules. The pre-charging monitoring is calculated.
Re bit 03 = 0:
The DC link voltage limit is calculated from p0210.
Re bit 03 = 1:
The DC link voltage limit is set to the maximum value of the power unit.
Re bit 05 = 1:
The status of the inputs/outputs for the power unit contactors is displayed in r0256.
This only applies to chassis power units with 3 AC line connection and line contactors.
The status display is only effective after parameter save and POWER ON.
p0230

Drive filter type motor side / Drv filt type mot

VECTOR_G
Can be changed: C2(1, 2)
Data type: Integer16
P-Group: Converter
Not for motor type: -
Min
0
Description:
Sets the type of the filter at the motor side.
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Signal name
Drive unit line supply voltage reduced
External pre-charging present
Automatically adapt Vdc_max limit
Contactor display inputs/outputs status
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Yes
No
Yes
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
4
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0000 0000 bin
0 signal
No
No
Yes
No
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
FP
-
-
-
9814
107