Event logging area (Un\G10000 to 27407)
The status related to the event logging function can be checked in this area.
Buffer memory name
Event logging
Event 1
information 1
occurrence count
Event 2 to 256
occurrence count
Event logging information 2 to 64
Event logging
Event logging
status 1
occurring status
Event logging status 2 to 64
■Event logging information 1 to 64 (Un\G10000 to 26383)
The number of times an event occurs is stored.
Event logging information area is comprised of 64 pieces of event logging information with the same data configuration.
Un\G10000 to 10255
Event logging information 1
Event logging information 2
Un\G10256 to 10511
Un\G26128 to 26383
Event logging information 64
● Event occurrence count
The event occurrence count is counted up for every event occurrence.
■Event logging status 1 to 64 (Un\G26384 to 27407)
The occurrence/restoration status of an event is stored.
The bit corresponding to the event No. occurring turns ON.
If the monitoring condition is "Value change", "Number of times", or "Order", the bit is always OFF.
0: Event restored
1: Event occurred
Event logging status area is comprised of 64 pieces of event logging status with the same data configuration.
Un\G26384 to 26399
Un\G26400 to 26415
Un\G27392 to 27407
APPX
336
Appendix 3 Buffer Memory
Address
Un\G10000
Un\G10001 to 10255
Un\G10256 to 26383
Un\G26384 to 26399
Un\G26400 to 27407
Event logging status 1
Event logging status 2
Event logging status 64
Description
The total number of times an event occurs is stored.
Same as event 1 occurrence count.
Details are the same as event logging information 1.
The occurrence/restoration status of an event is stored.
Details are the same as event logging status 1.
b15
+0
Event 1 occurrence count
+1
Event 2 occurrence count
Event 3 occurrence count
+2
+3
Event 4 occurrence count
Event 256 occurrence count
+255
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
+0
16
15
14
13
12
+1
32
31
30
29
28
+2
48
47
46
45
44
+3
64
63
62
61
60
+4
80
79
78
77
76
+5
96
95
94
93
92
+6
112
111
110
109
108
+7
128
127
126
125
124
+8
144
143
142
141
140
+9
160
159
158
157
156
+10
176
175
174
173
172
+11
192
191
190
189
188
+12
208
207
206
205
204
+13
224
223
222
221
220
+14
240
239
238
237
236
+15
256
255
254
253
252
b8
b7
b0
11
10
9
8
7
6
5
27
26
25
24
23
22
21
43
42
41
40
39
38
37
59
58
57
56
55
54
53
75
74
73
72
71
70
69
91
90
89
88
87
86
85
107
106
105
104
103
102
101
123
122
121
120
119
118
117
139
138
137
136
135
134
133
155
154
153
152
151
150
149
171
170
169
168
167
166
165
187
186
185
184
183
182
181
203
202
201
200
199
198
197
219
218
217
216
215
214
213
235
234
233
232
231
230
229
251
250
249
248
247
246
245
4
3
2
1
20
19
18
17
36
35
34
33
52
51
50
49
68
67
66
65
84
83
82
81
100
99
98
97
116
115
114
113
132
131
130
129
148
147
146
145
164
163
162
161
180
179
178
177
196
195
194
193
212
211
210
209
228
227
226
225
244
243
242
241

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec iq-rd81dl96Melsec iq-sw1dnn-rdlutl

Table of Contents