Error code
Error name
3072H
File access error
3073H
File format setting error
3074H
Data type setting error
3075H
Binary output format setting
error
3076H
Setting file error
3100H to 3101H
Module error
3110H
Module error
3111H
Incorrect file transfer destination
No. error
3112H
File transfer destination No.
non-setting error
3113H to 311BH
Module error
3120H
Incorrect e-mail address No.
error
3121H
E-mail address No. non-setting
error
3122H to 3123H
Module error
3130H to 315CH
Module error
31A0H to 31A1H
Setting file error
Error description
An error occurred when accessing the file.
An invalid setting has been made in the file format
setting.
Or the setting file is corrupted.
An invalid setting has been made in the data type
setting.
Or the setting file is corrupted.
An invalid setting has been made in the binary
output setting.
Or the setting file is corrupted.
There is no setting file.
Or the setting file is corrupted.
A module error has been detected.
A module error has been detected.
The file destination number is out of the range.
Or the setting file is corrupted.
Made a file transfer request for a file destination
number which was not set in the file transfer
setting.
Or the setting file is corrupted.
A module error has been detected.
The e-mail destination number is out of the range.
Or the setting file is corrupted.
Made an e-mail transmission request for an e-mail
destination number which was not set in the "E-
mail setting".
Or the setting file is corrupted.
A module error has been detected.
A module error has been detected.
There is no setting file.
Or the setting file is corrupted.
Corrective action
• Delete unnecessary files on the SD memory
card to ensure free space.
• Replace the SD memory card.
• Write the settings again with the Configuration
Tool.
• Replace the SD memory card.
• Write the settings again with the Configuration
Tool.
• Replace the SD memory card.
• Write the settings again with the Configuration
Tool.
• Replace the SD memory card.
• Write the settings again with the Configuration
Tool.
• Replace the SD memory card.
• Take measures to reduce noise.
• Reset the CPU module and switch it to RUN. If
the same error is displayed again, a hardware
failure may occur in high speed data logger
module. Please consult your local Mitsubishi
representative.
• Take measures to reduce noise.
• Reset the CPU module and switch it to RUN. If
the same error is displayed again, a hardware
failure may occur in high speed data logger
module. Please consult your local Mitsubishi
representative.
• Write the settings again with the Configuration
Tool.
• Replace the SD memory card.
• Write the settings again with the Configuration
Tool.
• Replace the SD memory card.
• Take measures to reduce noise.
• Reset the CPU module and switch it to RUN. If
the same error is displayed again, a hardware
failure may occur in high speed data logger
module. Please consult your local Mitsubishi
representative.
• Write the settings again with the Configuration
Tool.
• Replace the SD memory card.
• Write the settings again with the Configuration
Tool.
• Replace the SD memory card.
• Take measures to reduce noise.
• Reset the CPU module and switch it to RUN. If
the same error is displayed again, a hardware
failure may occur in high speed data logger
module. Please consult your local Mitsubishi
representative.
• Take measures to reduce noise.
• Reset the CPU module and switch it to RUN. If
the same error is displayed again, a hardware
failure may occur in high speed data logger
module. Please consult your local Mitsubishi
representative.
• Write the settings again with the Configuration
Tool.
• Replace the SD memory card.
4 TROUBLESHOOTING