■[Shared folder] tab
Item
Host name
User name
Password
Confirm password
Path
*1 When set with a domain name, the DNS server must be set in "DNS server setting" of the Network settings.
*2 The file cannot be transferred by specifying the user name that is involved in AD (Active Directory) domain. Specify the user name that
is not involved in AD domain.
*3 The transfer destination folder is not created. Create the transfer destination folder in advance.
If the transfer destination folder does not exist, an error occurs during file transfer.
*4 Use '/' as the delimiter between directories.
*5 Set the path so that the total length of "Host name" + "\" + "Folder path" + "\" + "Setting type folder name" + "\" + "Subfolder name" +
"Logging file name/report file name with extension" is up to 256 characters. (If the folder is other than Windows shared folder, then the
length can be up to 300 characters.)
The folder path has number of characters that includes the path (full path) starting from drive name up to shared folder.
■[Finish] tab
Item
File transfer setting name
[File transfer test] button
*1 The results of the file transfer test are not reflected to the buffer memory and on the "File transfer diagnostics" screen.
*2 If the network setting is changed, reset the CPU module after writing the settings, and then perform the file transfer test.
2 HIGH SPEED DATA LOGGER MODULE CONFIGURATION TOOL
138
2.4 Common Setting
Description
Set the host name of the file transfer destination as an IP address or domain name. (Up to 64 characters)
Set the logon user name to the file server. (Up to 20 characters)
Set the logon password to the file server. (Up to 127 characters)
Set the logon password again for verification. (Up to 127 characters)
Set the folder path (up to 256 characters) of the file transfer destination.
Description
Set the file transfer setting name. (Up to 32 characters)
If the file transfer setting name is duplicated, the suffixes ((1), (2), ...) will be added.
Performs a file transfer test to the set file server.
*2
*3*4*5
*1*2
*1