11.3.3 Setting Output Conditions

The following Computer Link parameters are displayed by specifying "Output setting" .to "Computer
Link".
Output Settings: Judgement/ Data Monitor/Both.
Select output data from the menu.
Selecting a PLC: Panasonic FP/MELSEC A+Q/MELSEC FX/OMRON C+CV+CS1/ AB SLC
Select a PLC to be used for Computer Link.
Start Register: Setting Range "0000 to 9999"
Specify the start register to output data to the PLC.
Store the data register of this number first and then the rest of the data registers.
Time Out (ms): Settable Range "20 to 200000" (in 1 ms unit)
Set the time limit from PLC to Response after data output if there is no response from PLC within the time
limitation, "Time out error" will occur and the device will output the error signal.
Output Data: 16 bit / 32 bit
Specify the bit length of output data. The available output dada bits are as follows:
16 bit: -32768 to 32767
32 bit: -2147483648 to 2147483647
But, Judgement results are output in digit unit regardless of output setting data.
Note that some of the registers from 0000 to 9999 are unavailable depending on type of PLC.