7.
Select "Sorting".
The subwindow is displayed.
Sorting:
This is a function that is necessary for using Feature
data (Calculation, Statistics and Data Monitor).
When the multiple images are detected, area and
gravity x/y, are arranged in descending/ ascending
order. You can specify "the number of the object" by
always arranging multiple objects in certain order.
8.
Select "Area", "X" or "Y".
9.
Select "Sorting Order".
Choose a sorting order based on the information specified at step 8.
10. Select "Descending"/"Ascending".
11. Select "OK Judge. Max." and press the ENTER key.
The value shown at the right of "OK Judge. Max" is highlighted.
OK Judge Max. /Min.:
These are the standard values for the object judged "OK". If the measurement results are within the range
between Min. and Max., it will be judged "OK".
12. Specify "OK Judge Max." and "OK Judge Min."
13. Press the A key to begin to test.
Check for a judgement result and detection count displayed in the message area of the monitor screen.
When testing using the CHECKER menu, operation procedure defers depending on the
image currently displayed.
Display Image
Live
Memory
Area: Sorts in descending order
X coordinate: Sorts in descending order
Action
Test after importing a new image.
Test with a Memory Image that is currently displayed.