3.3 Setting Conditions to Read Codes

Set the conditions to read code in the "Inspection Condition" menu
Setting Procedure
Inspection Condition
Grayscale Preprocess
Code Type
Code Model Parameter
Background
Recognize Reversed Code
Quality Check
Error Output
This is a preprocess filter for captured images. This is shared with
other checkers.
Select a code type to be read from 27 types.
Set the condition to read the code.
Bar code: Manual
2D code: Standard / Enhanced / Manual (Training)
Select a background color of the code.
It can be selected only for bar codes. Select the reverse condition of
the code, upside-down or left-to-right.
It can be selected only for 2D codes. Select whether to disable or
enable the quality check of the code.
Set the string to be output when a reading error occurs.