6.9.3 Setting Procedure
Inspection Conditions
1.
Proceed up to "Configure the setting for memory" at the second step following section 6.2.
The Smart Matching function works only for gray or differential images. When assigning the memory of an
extraction image, it malfunctions and displays an error code "E0100" in the message area.
2.
Select "Template".
3.
Select "Change".
4.
Set the range you want to register as a base image and decide
the start and end points.
Set a mask area if necessary.
The following messages may be displayed at template setting.
E0130 image Not has feature.
This message is displayed when the image in the template area has no or a few Features
(Contours). Check or if necessary change the settings of color extraction and monitor the
gray image and differential image. If you still cannot register the template after doing so,
adjust the size of the template area.
You can update it by receiving the input signals from the external device (or by re-registering
the current image). See page 214 for details.