Notes on Parallel Output
• The NPN open collector output is adopted. Note that the load current does not exceed the rated
voltage range.
• The AX40 has only a low capacity to carry current. It takes into consideration connections with a PLC,
etc. Do not connect to a heavy load such as a directly connected bulb. When such a requirement
exists, pass it through our Power-Photo relay.
• The output load should be within the specified range. See the figure shown below (maximum 24 mA
per 1 signal).
• The output circuit contains no internal fuse. When it is necessary to prevent output circuit burnout in
the event of an output load short circuit, attach an external fuse. However, there are cases when
internal elements cannot be protected in the event of a short circuit.
• The common flash line has a specialized terminal. Do not use it together with other common lines.