Setting procedure - Changing Accuracy, Detection Max. and Correspondence Min.:
1.
Highlight "Sequence".
The cursor moves to the "1ST" cell in the Step column.
2.
Select the phase you want to change.
The cursor moves to the cell in the Acc. column.
3.
Highlight the row in which the item you want to delete is and press the ENTER key.
Option
Description
Acc
Select accuracy available at this phase.
Det Max.
Specify the maximum number of Detection to be detected
at this phase. You can set to the number to detect at this
phase; the range from 01 - 64 can be specified. After
specifying the maximum detection number, press the
ENTER key.
Corr. Min.
Set minimum correlation within the range between 0.01
and 1.00. When changing the minimum correlation, press
the ENTER key.
4.
Press the C key.
The cursor advances to the next phase.
5.
After setting whole phases, press the C key.
The cursor moves to the Sequence tab.
Setting procedure- deleting a phase:
1.
Highlight "Sequence".
2.
Select the phase you want to delete and press the ENTER key.
The cell in the Acc. column is highlighted.
3.
Press the ENTER key.
4.
Choose "0" and press the ENTER key.
Now the phase is deleted.
106