Changing the Binary Level - Manual Setting
1.
Follow the steps 1 to 3 for automatically changing the binary level.
2.
Select "Upper" or "Lower".
3.
Change the values while checking the image, and then press the ENTER key to set the value.
4.
When you finish setting an "Upper" and a "Lower" value, press the C key.
The dialog message box saying "Do you want to register?" appears.
5.
Choose "YES" to register the values you have set. (Choose "NO" to cancel the registration of
the changes you have made.
Return to the checker menu.
Selecting the Binary Level Group
Follow the steps below to select the group, of which the optimum binary level has been already set.
1.
Select "Group Select" from the checker menu.
The subwindow for group selection is displayed.
2.
Choose "Select".
The list of binary groups is displayed. The binary level of the selected (highlighted) group and its binary
image are displayed.
3.
Select the desired group.
Return to the checker menu, and check to make sure that the selected group is displayed.