Problem: ERROR (error) signal is output while inspection is not performed.
Timing
When product types were
switched
When data in a CF card were
restored
When display images were
switched
When a template was
re-registered
During AXTOOL
communication
Cause
Product types were switched by specifying the number of the product
type that has not been created.
At the time of command input, error response "%Z" was returned from the
AX40 to the external device.
By using parallel (I/O) signal
Execution signal (FCT1/FCT2) was input by specifying an undefined
combination of IN1-IN3 or IN1 –IN7 signals.
By using serial command
When each command was input, the AX40 returns error response "%Z" to
the external device.
More than 30 seconds has passed since communication the AX40 and
external device was disconnected by removing the Ethernet cable while
the AX40 was communicating with AXTOOL.
273