Output Data Format - Panasonic MICRO-IMAGECHECKER AX40 User Manual

Hide thumbs Also See for MICRO-IMAGECHECKER AX40:
Table of Contents

Advertisement

11.2.4 Output Data Format

Output Order
Output Settings: When you specify Output settings "Both"(Judgement and Data monitor), the output
order is as follows.
Judgement
>
Data Monitor
Judgement:
Number of Digit
Number of Data
Value To Be Output
Data Monitor:
Number of Digit
Number of Data
Output Value
Example of Output
The following output results can be obtained for the same Data Conditions and different Output
Conditions.
Data Conditions
Judgement: D1 = NG, D2 = OK
Data Monitor: Data 1 = 215, Data 2 = -368
Output setting condition
1
Output Data: Both, Output
Digit: 5, Invalid Digit: Zero
2
Output Data: Both, Output
Digit: 5, Invalid Data: Delete
The order and format of output data are the same as the ones above regardless of output setting
of Ethernet or Computer Link.
1
Regardless of the digit number of output, one digital data are output per
Judgement.
Up to 8
1 = OK, 0 = NG
Varies
Depending on the number of Output Digit or Invalid Digit
Up to 50
-2147483648 to 2147483647
Output result
0
1
0
0
0
1
,
2
2
1
5
-
0
3
6
1
5
,
-
3
6
8 CR
8 CR