Power Failures - Huawei E9000 Troubleshooting Manual

Hide thumbs Also See for E9000:
Table of Contents

Advertisement

Huawei Servers
Troubleshooting
Model

5.6.1 Power Failures

The terms depicting server power status are defined as follows:
Diagnose and rectify power failures depending on the symptoms.
Issue 20 (2020-09-25)
Power connected: The server is connected to a power source and the power
indicator is on.
Standby: The server is connected to a power source and the power indicator is
steady yellow.
Power-on: The server is on and the power indicator is steady green.
POST: The server is in the power-on self-test process.
NO TE
● If a fault can be located using logs or tools, see "Handling Procedure". If a fault needs
to be rectified quickly onsite, see "Quick Recovery Method".
● For more fault symptoms and solutions, see the
Computing Case Library is available only to Huawei engineers and partners.
Copyright © Huawei Technologies Co., Ltd.
5 Diagnosing and Rectifying Faults
Minimum
Configuration
Two DIMMs in the
DIMM000(A) and
DIMM100(A) slots
Computing Case
Remarks
Library. The
79