Indicator
Table 5-9 Network port indicators
Indicator
Connection status
indicator/Data
transmission
status indicator for
a 10GE optical
port
Issue 20 (2020-09-25)
Status
Off
Status
Steady
green
Blinking
green
Off
Copyright © Huawei Technologies Co., Ltd.
5 Diagnosing and Rectifying Faults
Meaning
The PSU has no
power input or is
faulty.
Meaning
The network port is
connected properly.
Data is being
transmitted.
The network port is
not connected.
Diagnosis
1. Check whether
the PSU is
faulty.
2. Check whether
the external
power supply is
normal.
Diagnosis Procedure
N/A
1. Connect the port
to another switch,
optical fiber, and
optical module to
check whether the
original switch
and optical fiber
are normal and
whether the type
and speed of the
original optical
module are
correct.
2. Check whether
the ports on the
switch and NIC
are up.
3. Check whether
the NIC is
operating
properly.
50