Huawei E9000 Troubleshooting Manual page 61

Hide thumbs Also See for E9000:
Table of Contents

Advertisement

Huawei Servers
Troubleshooting
Indicator
transmission
status indicator for
a 10GE electric
port
Data transmission
rate indicator for a
10GE electrical
port
Issue 20 (2020-09-25)
Status
Blinking
green
Off
Steady
yellow
Steady
green
Copyright © Huawei Technologies Co., Ltd.
5 Diagnosing and Rectifying Faults
Meaning
Data is being
transmitted.
The network port is
not connected.
The link rate is 1
Gbit/s.
The link rate is 10
Gbit/s.
Diagnosis Procedure
1. Connect the port
to another switch,
optical fiber, and
optical module to
check whether the
original switch
and optical fiber
are normal and
whether the type
and speed of the
original optical
module are
correct.
2. Check whether
the ports on the
switch and NIC
are up.
3. Check whether
the NIC is
operating
properly.
1. Connect the port
to another switch,
optical fiber, and
optical module to
check whether the
original switch
and optical fiber
are normal and
whether the type
and speed of the
original optical
module are
correct.
2. Check whether
the ports on the
switch and NIC
are up.
3. Check whether
the NIC is
operating
properly.
N/A
52

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents