Troubleshooting
Table 5-5 SAS/SATA drive status indicators
Drive Active
Indicator
Steady green
Blinking green
Steady green
Blinking green
Steady green,
blinking green, or
off
Off
Table 5-6 NVMe drive indicators
Drive Active
Indicator
Steady green
Blinking green at
2 Hz
Off
Issue 20 (2020-09-25)
Drive Fault
Indicator
Off
Blinking yellow
Steady yellow
Off
Drive Fault
Indicator
Off
Copyright © Huawei Technologies Co., Ltd.
5 Diagnosing and Rectifying Faults
Meaning
The drive is
operating properly.
Data is being read
from or written to
the drive.
The server is
locating the drive
or rebuilding RAID.
The drive is faulty.
The drive is faulty
or not detected.
Meaning
The NVMe drive is
detected and
working properly.
Data is being read
from or written to
the NVMe drive.
The NVMe drive is
not detected.
Diagnosis
N/A
Log in to the
iMana 200 or
iBMC and use
FusionServer
Tools Toolkit
or
Smart
Provisioning
to
check the drive
faults.
Check whether
the drive is
connected, or log
in to the iMana
200 or iBMC and
use
FusionServer
Tools Toolkit
or
Smart
Provisioning
to
check the drive
faults.
Diagnosis
N/A
46