Huawei E9000 Troubleshooting Manual page 54

Hide thumbs Also See for E9000:
Table of Contents

Advertisement

Huawei Servers
Troubleshooting
Indicator
UID button/
indicator
Step 2 View iMana 200 or iBMC system event logs (SELs) to locate faults.
Step 3 Check the status indicators of the components.
Issue 20 (2020-09-25)
Status
Steady blue
Blinking blue
Off
Table
5-5,
Table
5-6,
describe the meanings of the SAS/SATA drive status indicator, NVMe drive
status indicator, M.2 FRU indicator, PSU status indicator, network port
indicator, and FlexIO card status indicator, and the corresponding handling
procedures.
Table 5-11
describes the meanings of the indicators for each module of the
RH5885 V2, RH5885 V3, and RH5885H V3, and the corresponding handling
procedures.
Table 5-12
describes the meanings of the indicators for each module of the
RH8100 and X6800, and the corresponding handling procedures.
Table 5-13
describes the meanings of the aggregation network port
indicators on the X6000, X6800, and X6800 V5, and the corresponding
handling procedures.
Table
5-14,
Table
5-15, and
management module indicator, E9000 fan module indicator, and E9000 switch
module indicator, and the corresponding handling procedures.
Table 5-17
and
Table 5-18
indicator and network port indicator on the Atlas 800 training server (model
9010), and the corresponding handling procedures.
Copyright © Huawei Technologies Co., Ltd.
Meaning
The server is
being located.
The server is
distinguished
from multiple
servers that have
also been located.
The server is not
being located or is
not powered on.
Table
5-7,
Table
5-8,
Table 5-16
describe the meanings of the MM910
describe the meanings of the fan module
5 Diagnosing and Rectifying Faults
Diagnosis
NOTE
● The UID
button/
indicator helps
identify and
locate a server.
You can turn
on or off the
UID indicator
by manually
pressing the
UID button or
running a
command on
the iBMC CLI or
remotely
controlling the
UID indicator
on the iMana
200 or iBMC
WebUI.
● You can hold
down the UID
button for 4 to
6 seconds to
reset the iMana
200 or iBMC.
Table
5-9, and
Table 5-10