Step 5 Enter the value representing the serial port to be connected, and press Enter.
The serial port screen is displayed. On this screen, you can perform operations
such as configuration and query.
----End
8.18 Logging In to a Compute Node, Passthrough
Module, or Switch Module by Using the SOL Function
of the MM920/MM921
Scenarios
You can use the SOL function of the management module to access a compute
node, passthrough module, or switch module in a chassis for remote maintenance
of the E9000.
Prerequisites
Conditions
Data
You have obtained the following data:
Procedure
Step 1 Use an SSH tool and the floating IP address of the MM920/MM921 to log in to
the CLI.
Issue 20 (2020-09-25)
If you enter a passthrough module slot number, the following serial port
information is displayed:
1 BMCcom
NO TE
You can press Ctrl+R once to return to the slot number selection screen shown in
press Ctrl+R twice to exit the SOL screen.
You have logged in to the MM920/MM921 CLI by using the floating IP
address of the MM920/MM921.
There is no jumper cap over the pins on the mainboard of the compute node,
passthrough module, or switch module.
Username and password for logging in to the management module. The
default username and password of the MM920/MM921 are Administrator
and Admin@9000 respectively.
Username and password for logging in to the compute node to be connected.
The default username and password are Administrator and Admin@9000
respectively.
Password for logging in to the passthrough module or switch module to be
connected The default password is Huawei12#$.