Logging In To A Compute Node, Passthrough Module, Or Switch Module By Using The Sol Function Of The Mm910 - Huawei E9000 Troubleshooting Manual

Hide thumbs Also See for E9000:
Table of Contents

Advertisement

Huawei Servers
Troubleshooting
8.17 Logging In to a Compute Node, Passthrough
Module, or Switch Module by Using the SOL Function
of the MM910
Operation Scenario
You can use the Serial over LAN (SOL) function of the management module to
access a compute node, passthrough module, or switch module in a chassis for
remote maintenance of the E9000.
Prerequisites
Conditions
Data
You have obtained the following data:
Procedure
Step 1 Use an SSH tool and the floating IP address of the MM910 to log in to the
MM910 CLI.
In this document, PuTTY is used as the SSH tool. For details, see
to a Server Over a Network Port by Using
Step 2 Log in to the SOL screen.
telnet 0 1101
*=====================================================================*
*
*
*=====================================================================*
user name:
Issue 20 (2020-09-25)
You have logged in to the MM910 CLI by using the floating IP address of the
MM910.
There is no jumper cap over the pins on the mainboard of the compute node,
passthrough module, or switch module.
User name and password for logging in to the management module. The
default user name of the MM910 is root, and the default password is
Huawei12#$.
User name and password for logging in to the compute node to be
connected. The default user name is root, and the password is Huawei12#$.
Password for logging in to the passthrough module or switch module to be
connected The default password is Huawei12#$.
Welcome to SMM SOL Server
Please log in with SMM account and password.
Copyright © Huawei Technologies Co., Ltd.
8 Common Operations
8.15 Logging In
PuTTY.
*
*