<HUAWEI>system-view
[~HUAWEI]interface MEth 0/0/0
[~HUAWEI-MEth0/0/0]display this
Step 3 (Optional) After logging in to the switch module by using a serial port or the SOL
function, run the following commands on the Ethernet switching plane CLI to
query and set the IP address of the management network port so that the switch
module can properly communicate with the FTP server:
<HUAWEI>system-view
[~HUAWEI]interface MEth 0/0/0
[~HUAWEI-MEth0/0/0]ip address
[~HUAWEI-MEth0/0/0]commit
[~HUAWEI-MEth0/0/0]display this
#
interface MEth0/0/0
ip address 192.168.100.123 255.255.255.0
#
return
[~HUAWEI-MEth0/0/0]quit
[~HUAWEI]quit
Step 4 Obtain the log information.
1.
Issue 20 (2020-09-25)
If the command output is as follows with no IP address displayed, go to
3
#
interface MEth0/0/0
#
return
If the command output contains an IP address and gateway address, go to
Step
4.
#
interface MEth0/0/0
ip address 192.168.100.123 255.255.255.0
#
return
NO TE
Skip this step if you log in to the switch module by using a network port.
View the log file system.
<HUAWEI>system-view
Enter system view, return user view with return command.
[~HUAWEI]diagnose
Warning: Enter diagnose view, return user view by pressing Ctrl+Z.
Info: The diagnose view is used to debug system hardware and software. Misuse of some commands
in this view will affect system performance. Therefore, use these commands with the guidance of
Huawei engineers.
[~HUAWEI-diagnose]collect diagnostic information
Info: Succeeded in collecting diagnostic information in slot 3.
[~HUAWEI-diagnose]display diagnostic-information diag-info.txt
Copyright © Huawei Technologies Co., Ltd.
192.168.100.123 24
4 Collecting Information