Binding Members to the Stack
Assigning a Stack Backup Switch
308
G8264 Application Guide for ENOS 8.4
RS G8264(config)# show stack attachedswitches
Attached Switches in Stack:
asnum MAC csnum State
A1 74:99:75:d1:fc:00 C1 IN_STACK
A2 74:99:75:d0:99:00 C2 IN_STACK
A3 74:99:75:d1:e9:00 C3 IN_STACK
RS G8264(config)#
You can bind Member switches to a stack csnum using either their asnum or MAC
address :
RS G8264(config)# stack switchnumber <csnum> mac <MAC address>
‐or‐
RS G8264(config)# stack switchnumber <csnum> bind <asnum>
To remove a Member switch, execute the following command:
RS G8264(config)# no stack switchnumber <csnum>
To bind all units of a stack, use the command:
RS G8264(config)# stack bind
The stack bind command automatically assigns switch numbers to all attached
switches in the stack that do not yet have a number assigned.
To define a Member switch as a Backup (optional) which will assume the Master
role if the Master switch fails, execute the following command:
RS G8264(config)# stack backup <csnum>