In OpenFlow 1.3, if a match is not found for an arriving packet, the packet is either 
dropped or sent to the controller. If sent to the controller, the controller decides 
which action(s) to perform on all packets from the same flow. The decision is then 
sent to the switch and cached as an entry in the switch instance's flow table. If the 
controller decides to add the flow, it sends a flow add message to the switch. The 
switch then adds the flow in its flow table. The next arriving packet that belongs to 
the same flow is then forwarded at line‐rate through the switch without consulting 
the controller.
By default, packets that don't match any of the existing flow entries are dropped. 
To set up an OpenFlow instance to send non‐matching packets to the controller 
instead of dropping them, use the following commands:
RS G8264(config)# openflow instance <instance ID>
RS G8264(config­openflow­instance)# table­miss controller